Master these points, so that you will no longer be troubled by the maintenance of the laboratory emulsifier

 Medicated cream is a relatively common paste preparation, and its preparation requires corresponding emulsifying equipment. In recent years, with the rapid development of the pharmaceutical industry and the acceleration of approval and review, more and more medicated cream products have been approved for the market. Under the broad market demand, the medicated cream market has continued to grow, It also brings more opportunities for the relevant emulsification machines and equipment.

Among them, the laboratory emulsifying machine is a device specially used for experiments. It has the characteristics of high efficiency, rapidity and uniformity, and is suitable for experiments or small-scale production. It is understood that the laboratory emulsifier makes the particles in the liquid, solid or solid-liquid mixture evenly distributed to the entire material through the action of mechanical external force, and then undergoes uniform refining, dispersion and emulsification to form a stable emulsion.

However, no matter what grade of laboratory emulsifier it is, users should pay attention to the maintenance of the equipment during use. In this regard, some manufacturer's technicians have made a brief introduction to equipment maintenance knowledge, let's see what you have mastered?


First, when the user uses the emulsifier, the liquid material must be continuously input or maintained in a certain amount in the container. The purpose of this is to avoid empty machine operation and prevent equipment from being damaged due to high temperature or crystal solidification of materials in the work.

Second, after the experiment or small-scale production is completed, the laboratory emulsifying machine must be cleaned, which can not only maintain the working efficiency of the stator and rotor, but also protect the sealing of the emulsifying machine.

In addition, the technicians suggested that if necessary, a cleaning cycle device can be designed and installed on the periphery of the equipment to facilitate cleaning and keep it clean.

Third, the laboratory emulsifier starts the motor after confirming that the cooling water of the machine seal is turned on. It should be noted that the rotation of the motor should be consistent with the rotation mark of the main shaft before it can run, and do not reverse.

Fourth, it is strictly forbidden for metal chips or hard and difficult-to-break debris to enter the working cavity of the emulsifier, so as to avoid catastrophic damage to the working stator, rotor and equipment.

Equipment maintenance personnel need to regularly check the stator and rotor. If the wear is found to be excessive, the corresponding parts should be replaced in time to ensure the effect of dispersion and emulsification.

Fifth, according to the different media used by the user, the user must clean the inlet and outlet filters regularly, so as not to reduce the amount of feed and affect the production efficiency.

In addition, the material entering the working chamber must be fluid, and no dry powder or agglomerate material is allowed to directly enter the machine, otherwise it will cause boring and damage the emulsifier.

Sixth, when the laboratory emulsifier is running, if there is liquid leakage at the shaft, the pressure of the machine seal must be adjusted after the machine is stopped. In case of abnormal sound or other faults, it is also necessary to stop the machine immediately for inspection, and then run it after the fault is eliminated. After shutdown, the working chamber, stator and rotor should be cleaned.

Seventh, the safety of equipment and personnel needs to be guaranteed. Generally speaking, before users use the laboratory emulsifier, enterprises need to formulate corresponding safety production operation procedures to ensure the safety of operators and equipment. In the electrical control system, it is also necessary for the user to set up a safety protection system and have a good and reliable electrical motor grounding device.

For more information go to https://www.yekeey.com/

评论

此博客中的热门博文

Brief Introduction and Advantage of Laboratory high shear homogenizer

  Brief Introduction LR-5 high shear mixer series is the most popular machine in our laboratory mixer series. It is the ideal choice for routine laboratory work, R&D, QA analysis and small-scale production in all industries. LR-5 high shear mixer series has a wide range of industrial applicability, through the replacement of stator and rotor, it can easily achieve mixing, homogenization, emulsification, dispersion, dissolution and other functions, which is incomparable with other similar equipment efficiency and flexibility. In addition, the LR-5 high shear mixer series is equipped with special on-line hybrid modifications, which can provide experimental data for large-scale continuous production. Advantage   All SUS304 food-grade stainless steel shell, corrosion-resistant, easy to clean, easy to handle. With servo motor, the speed can be adjusted arbitrarily in the range of 600-8000rpm, and with feedback device, the speed is stable and reliable, which can be used for refe...

Bottom homogeneous vacuum emulsifier for laboratory dispersion and emulsification

  A customer inquired about the laboratory emulsifier   a year ago. During the consultation, the customer emphasized that it must be a bottom homogeneous vacuum emulsifier . Because scale-up production requires the use of a bottom homogeneous vacuum emulsifier, the laboratory should be consistent.   After docking their specific process requirements with the customer, we recommended the ZJR-5 laboratory   bottom homogeneous vacuum emulsifier to the customer and quoted it.   Through the quotations and communication comparisons of many emulsifier manufacturers , the customer felt that this laboratory bottom homogeneous   emulsifier from YeKeey was more cost-effective, and the communication with the sales engineer was smoother, so he chose this customized ZJR-5 laboratory bottom homogeneous emulsifier. The equipment is now completed and ready to ship!    The ZJR-5 laboratory bottom homogeneous   vacuum emulsifier   is dexterous and convenien...

WHAT KIND OF CONFIGURATION DOES THE SALAD DRESSING EMULSIFYING MACHINE NEED?

    YeKeey salad dressing emulsifying machine is generally composed of two types of raw materials, water, and oil phase, through the action of a high-speed shearing homogenizer, so that the two-phase materials can be rapidly fused. In theory, the equipment that can prepare salad dressing is mainly in YeKeey products. There are 3 series: 1. ZJR Series Vacuum Homogeneous Emulsifier Features:  The main body is composed of a frame scraper, two-way stirring, a  high-speed homogenizer ,  and an  emulsifying tank . It can be equipped with a pre-treatment water and oil pot. This unit has the characteristics of easy operation, stable performance, good homogeneity, high production efficiency, convenient cleaning, reasonable structure, less floor space, and a high degree of automation. 2. MC Series External Circulation Emulsifier Features:  The external circulation online  vacuum emulsification mixer  adopts a pipeline...